Pump Setting Gauges
for Calibrating Chemical Pumps



  • Pump Setting Gauges

    KENCO Engineering - Pump Setting Gauge for Calibrating Chemical Pumps






    EQUIPMENT FEATURES

    • Maximum Static Head Pressure (Must be shielded if there is any pressure present in system).
    • Pyrex Gauge Cylinder is standard. Plastic tubing may be substituted.
    • Fluorocarbon o-ring seals are standard. Other elastomers are available.
    • Gauge Glass Repair Kits include calibrated scale to insure gauge accuracy.
    • Gauges are available with (6) standard options on scale calibration units (GPH, LPH, GPD, LPD, GBV, &  LBV).

    GAUGE SPECIFICATIONS

            A B
    Gauge Model Number Maximum Pump Rate Scale Units Based on a 1 Min Test Inlet Port Size CS/SS End Plates PVC/
    CPVC End Plates
    Standard/
    Lexan Shield
    Metal Guard *Glass Repair Kit
    30016 16 GPD .5 GPD 1/4" NPT 16-1/4" 16-1/2" 2-1/2" 3-1/2" 30016-RK
    30030 30 GPD 1 GPD 1/4" NPT 12-7/8" 13-3/8" 2-1/2" 3-1/2" 30030-RK
    30060 60 GPD 1 GPD 1/2" NPT 14-15/16" 15-7/16" 2-1/2" 3-1/2" 30060-RK
    30096 96 GPD 2 GPD 1/2" NPT 14-15/16" 15-7/16" 2-1/2" 3-1/2" 30096-RK
    30144 144 GPD 5 GPD 1/4" NPT 12-7/8" 13-3/8" 3" 4" 30144-RK
    30216 216 GPD 5 GPD 1/2" NPT 12-7/8" 13-3/8" 3-1/2" 4-1/2" 30216-RK
    30280 280 GPD 5 GPD 1/2" NPT 12-7/8" 13-3/8" 3-1/2" 4-1/2" 30280-RK
    30420 420 GPD 10 GPD 1/2" NPT 12-7/8" 13-3/8" 4" 5" 30420-RK
    30580 580 GPD 10 GPD 3/4" NPT 12-7/8" 13-3/8" 4-1/2" 5-1/2" 30580-RK
    30700 700 GPD 20 GPD 3/4" NPT 12-7/8" 13-3/8" 5" 6" 30700-RK
    31440 1440 GPD 25 GPD 1" NPT 14-3/8" 14-3/8" 7" 8" 31440-RK

    *REPAIR KIT: Add suffix -V-GPH to glass repair kit part number for O-Ring seal material and scale units required. See gauge ordering information below for O-Ring seal/scale units available.

    GAUGE MODEL NUMBER/ORDERING INFORMATION

    GAUGE MODEL NUMBER END PLATE MATERIAL O-RING SEAL MATERIAL SCALE UNITS SIGHT TUBE SHIELD OPTIONS
    See

    chart

    above

    CS
    (Carbon Steel)
    S4
    (304 Stainless Steel)
    S6
    (316 Stainless Steel)
    P
    (Polyvinyl Chloride)
    C
    (Chlorinated Polyvinyl Chloride)
    A
    (Aflas)
    B
    (Buna-N)
    EP
    (Ethylene Propylene)
    TES
    (Teflon Encapsulated Silicone)
    V
    (Flourocarbon)
    GPH
    (Gallons Per Hour)
    LPH
    (Liters Per Hour)
    GPD
    (Gallons Per Day)
    LPD
    (Liters Per Day)
    GBV
    (Gallons By Volume)
    LBV
    (Liters By Volume)
    S
    (Standard/No Shield)
    LS
    (Lexan Shield)
    GG
    (Expanded Metal Guard)

    SCALE UNITS: Rate scale units are based on a one minute test
    MODEL NUMBER EXAMPLE: 30016-CS-V-GPD-S